![mitsubishi srk35gz-l1 manual mitsubishi srk35gz-l1 manual](https://data2.manualslib.com/product_thumbs/23/113/11245/1124472_srk09ch_product.png)
- Mitsubishi srk35gz l1 manual manuals#
- Mitsubishi srk35gz l1 manual serial#
- Mitsubishi srk35gz l1 manual manual#
- Mitsubishi srk35gz l1 manual series#
Electrical wiring Meaning of marks Symbol Parts name Symbol Parts name Symbol Parts name Capacitor for FMI Reactor Transformer Compressor motor Flap motor Varistor Fuse Room temp. 3 Exterior dimensions (1) Indoor unit Unit: mm Model SRK2. 5GZ- L1 Total one way piping length (m) Outdoor unit is higher. The indoor unit is composed of room air cooling or heating equipment with opera- tion control switch and the outdoor unit is composed of condensing unit with compressor.
Mitsubishi srk35gz l1 manual series#
Specific features The “Mitsubishi Daiya” room air- conditioner: SRK series are of split and wall mounted type and the unit consists of indoor unit and outdoor unit with refrigerant precharged in factory.
Mitsubishi srk35gz l1 manual manuals#
Related Manuals for Mitsubishi Daiya SRK25GZ-l1. Instructions & manuals for MITSUBISHI INVERTER SRK35GZ-L1 MITSUBISHI > MITSUBISHI > INVERTER > INVERTER SRK35GZ-L1 > INVERTER. WALL MOUNTED TYPE ROOM AIR- CONDITIONER Split system, Air to air heat pump type SRK2.
Mitsubishi srk35gz l1 manual manual#
(When it is 5 to 15 m, add 20 g refrigerant per 2.com › Mitsubishi Srk35gz L1 Manual Meat ▼ The values for performance and power consumption shown in brackets indicate the range from minimum to maximum.
Mitsubishi srk35gz l1 manual serial#
Protection, frosting protection, serial signal error protection, indoor fan motor error protection R22 1.1 (Pre-Charged up to the piping length of 5m)Ĭompressor: Overheat protection, heating overload protection (High pressure control), overcurrent (When it is 5 to 15 m, add 20 g refrigerant per meter.) (Purging is not required even in the short piping.) The refrigerant quantity to be charged includes the refrigerant in 5 m connecting piping. The operation data are applied to the 220/240V districts respectively. The values for performance and power consumption shown in brackes indicate the range from minimum to maximum. Notes (1) The data are measured at the following conditions. R22 0.64 (Pre-Charged up to the piping length of 5m)Ĭompressor: Overheat protection, heating overload protection (High pressure control), overcurrent protection, serial signal error protection, indoor fan motor error protection We are constantly trying to do better service to our customers by installing such judges that show abnormality of operation as Memory flap: Once the flap position is set, the unit memorizes the position and continues to operate at the same position from Swing: This will swing the flap up and down. Natural flow (AUTO): Flap operation is automatically control. The flap can be automatically controlled by operating wireless remote control. Constant room temperature by fine-tuned control after theįuzzy control calculates the amount of variation in the difference between the suction air temperature and the setting temperature in compliance with the fuzzy rules in order to control the air capacity and the inverter frequency. Unit fans controlled to changes in frequency, thus controlling the power.Īllowing quick heating/cooling operation during start-up period.
![mitsubishi srk35gz-l1 manual mitsubishi srk35gz-l1 manual](https://data2.manualslib.com/product_thumbs/17/84/8388/838730_srk25zds_product.png)
The rotational speed of a compressor is changed in step in relation to varying load, to interlock with the indoor and outdoor (1) Inverter (Frequency converter) for multi-steps power control The indoor unit is composed of room air cooling or heating equipment with operation control switch and the outdoor unit is composed of condensing unit with compressor. Outdoor unit with refrigerant precharged in factory. The “Mitsubishi Daiya” room air-conditioner: SRK series are of split and wall mounted type and the unit consists of indoor unit and Precautions for wireless remote controller installation and OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER.